The Perseus 60kV X-Ray Generator range are a series of high voltage power supplies designed for non-destructive testing (NDT). Additionally the Perseus is a highly stable and accurate X-Ray power source with an output current of 0-1mA.
Industrial 60kV X-Ray Generator
Aside from NDT, other areas of use include material analysis, security checking, computed tomography, medical imaging and diagnostics and in specific environments that require a dependable high voltage x-ray source.
X Ray Power Supply Controls
It can either be controlled locally or by remote, and therefore the output voltage, output current and maximum filament current can be adjusted at either the front panel or remote control.
Other Power Options
For 100kV Negative output X-Ray generator power supplies take a look at the Perseus 100kV
Input Voltage | 230VAC |
---|---|
Input Frequency | 50Hz, 60Hz |
Output Voltage | 60kV |
Output Power | 1800W |
Polarity | Negative |
Output Adjustable Range | 0 to 100% Voltage |
Voltage Ripple | < 0.05% |
Load Regulation | 0.01% |
Line Regulation | 0.01% |
Power Factor | 0.92 |
Operating Temperature | 0°C, 10°C, 15°C, 35°C, 40°C, 50°C |
Operating Humidity | 0 to 90% non-condensing |
Cooling Method | Air |
Control | Local and Remote |
Monitoring | Local and Remote |
The output voltage, output current and the maximum filament current setup is achieved by the 10 turn potentiometers on the front panel.
Details of the output voltage feedback, output current feedback and the filament current feedback are displayed on the 4 digital screens on the front panel.
The default and working status are indicated by LED lights and the remote control mode is achieved by connecting a 25 pin connector on the rear panel.
This power supply contains hazardous voltages and stored energy, as such any contact with the output may result in fatal injury. It should only be used and maintained by trained personnel.
The area where the power supply is to be used should be kept clean and dry.
Always keep a safe distance from the output connector and any items connected to it.
Ensure that a secure connection is made between the Earth side of the load and the Green and Yellow Earth lead.
For requirements, other than those specified on the 60kV and 100kV X-Ray Generators, please do not hesitate to contact the factory.
N.B. Design improvements may lead to specification changes.
Our expert team can help you with any questions you may have about this product. Complete the form for a call back or call us during office hours.
Genvolt Engineers have also offered customised technical support to hundreds of customers, who represent countless agencies, research departments and global organisations for multiple products across many applications. The people that work with us know they can trust our vision, products and services as we build strong partnerships.
Our vision is to provide customers, of high voltage technologies, with a high level of support and industry-leading expertise so as to deliver the best solution to their requirements.