The Vulcan HV Power Supply has been designed principally to address the demanding requirements of electron guns, including electron beam welders. Although this is the mainstay of this range the power supply has the ability to be used as a high voltage capacitor charging power supply with its formidable output voltage of 200kV and an output power rating of 24kW. The Vulcan power supplies provide a rapid response to load changes and are highly tolerant of gun arcs. This makes them suitable for use as X-ray power supplies and for a variety of scientific research applications.
An RS485 serial link enables the user to control the output and to view a diagnostic output, using a terminal or host computer. Alternatively, analogue inputs may be used to control the outputs.
As this power supply can be adapted to deliver outputs from 10kW to 24kW and up to 200kV, the specification below is just an example of the numerous options available.
Input Voltage | 400VAC three phase |
---|---|
Input Frequency | 50Hz, 60Hz |
Output Voltage | 100kV, 120kV, 150kV, 180kV, 200kV, 60kV |
Output Power | 10KW, 12KW, 14.4KW, 15KW, 16KW, 18KW, 20KW, 24KW |
Output Adjustable Range | 0 to 100% Voltage |
Load Regulation | 0.03% |
Line Regulation | 0.03% |
Control | Local and Remote |
Monitoring | Local and Remote |
The input voltage range can be between 380/220VAC -10% to 415/240VAC +10%, three phase, four-wire plus Earth, 50 or 60Hz. The inputs are power-factor corrected. In cases where no neutral connection is available, this should be specified at time of order. Supplies may also be 210/120VAC three wire but this must also be specified at time of order.
Output voltage | The output voltage may be set to any value up to 60kV negative (in this example). Values below 500V are considered to be outside the normal operational range and are not subject to specification. |
---|---|
Output stored energy | Any level of current may be drawn from the supply up to a maximum of 250mA. Automatic reduction of output voltage occurs above approximately 275mA. |
Ripple | 60V pk. to pk. at twice the main oscillator frequency. The oscillator operates at 50 to 60kHz and so the main ripple component of the output will be at 100 to 120kHz. This assumes that the high voltage cable is at least 1000pF. There is also a ripple component at 100Hz (for a 50Hz supply). This is below 60V pk. to pk. but is measured separately from the converter frequency component. Note that converter frequency ripple is mainly related to load current, not voltage, while mains frequency ripple is related to output power. |
Regulation | Line: Less than 15V for a 25VAC change in supply voltage. Load: Less than 15V for a 25mA (10%) to 250mA (100%) change in load current Analogue inputs and outputs. |
HV command input | 0 to +10V = 0 to 60kV |
mA command input | 0 to +10V = 0 to 250mA |
Bias command input | 0 to +10V = 0 to -2000V (Standby Mode) |
HV feedback output | 0 to +10V = 0 to 60kV |
mA feedback output | 0 to +10V = 0 to 250mA |
Bias feedback output | 0 to +10V = 0 to -2000V |
Filament feedback output | 0 to +10V = 0 to 100A. |
Dimensions | 56cm x 78cm x 100cm |
---|---|
Mass | 250kg |
Notre équipe d’experts peut vous aider à répondre à toutes les questions que vous vous posez sur ce produit. Remplissez le formulaire pour être rappelé ou appelez-nous pendant les heures de bureau.
Les ingénieurs de Genvolt ont également offert un support technique personnalisé à des centaines de clients, qui représentent d’innombrables agences, départements de recherche et organisations mondiales pour de multiples produits dans de nombreuses applications. Les personnes qui travaillent avec nous savent qu’elles peuvent faire confiance à notre vision, à nos produits et à nos services, car nous construisons des partenariats solides.